With up to 48 zones of protection, graphic keypad support and dual partitions, the VISTA-20P control panel gives your customers the ability to send alarm.
With up to 48 zones of protection, graphic keypad support and dual partitions, the VISTA20P control panel gives your customers the ability to send alarm.
  • IP alarm reporting and uploading/ downloading capability for Internet and Intranet use via iGSMV4G, 7845i-ENT, GSMV4G or GSMX4G
  • Supports four graphic touchscreen keypads
  • Wireless keys can be programmed without using zones
  • Eight on-board hardwired zones standard (15 when Zone Doubling feature is used)
    – 40 hardwire expansion zones
    – 40 wireless expansion zones
  • Two low current on-board trigger outputs
  • 100 Event Log viewable at system keypads with time/date stamp
  • 48 system user codes assignable to either partition
  • Expandable to 48 total zones when used with hardwired and/or wireless expansion modules
  • Two independent partitions plus a common partition
    – Global Arming from any system keypad
    – Go to function to view or operate one partition from the other
    – Separate partition account numbers
  • 16 output devices
    – Relays (Model 4204 Relay Modules, or 4229 Expansion Module)
  • Four installer-configurable zone types allows the installer to create custom zone types by assigning all zone attributes
  • Supports four-wire and up to 16 two-wire smokes
    – Works with Sentrol CleanMe™ maintenance signal
  • Multiple actions on output devices depending on system state
    – Turns lights off when system arms
    – Turns the same light on when system disarms
    – Flashes same lights when system is in alarm
  • Built-in phone line cut monitor with programmable delay and annunciation options
    – Display on system keypads
    – Trigger local sounders
    – Trigger system bell

Security Dealer Features

  • Automatic System Load Shed
    – During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries.
  • Dynamic Signaling
    – Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet radio

Valuable End-User Features

  • Viewable on system keypads:
    – Exit countdown
    – Time and date display
    – Event log
  • Auto keypad backlighting on entry
  • Keyswitch arming
  • Programmable macro buttons and single-button arming
  • Supports a variety of wireless remote controls for single-button operation
  • User Scheduling
    – Latchkey reports to pagers
    – Auto arm/disarm
    – “User access” time windows
  • VIP Module allows system control from any touchtone phone
  • Chime by zone

ELECTRICAL

  • Aux. power 12 VDC, 600mA maximum
  • Seven hour standby at 400mA aux. load with four amp hour battery
  • 16.5 VAC/25 VA transformer
  • Alarm output 12 VDC, 2.0 amps max. – For UL installations, combined aux. and alarm output cannot exceed 700mA OUTPUT CONTROL
  • Supports up to four relay boards (up to 16 relays)
  • Optional X-10 transformer/interface (part no. 4300) may be used to control up to 16 X-10 receiving devices

ZONES

  • Eight hardwired zones (15 with zone doubling)
  • Selectable response 10msec, 350msec, 750msec
  • Assignable to any partition
  • 20 selectable zone types plus four configurable zone types
  • Programmable swinger suppression